Author Affiliations
Abstract
1 Key Laboratory on High Power Laser and Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, China
2 Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, China
3 Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, China
As optical parametric chirped pulse amplification has been widely adopted for the generation of extreme intensity laser sources, nonlinear crystals of large aperture are demanded for high-energy amplifiers. Yttrium calcium oxyborate (YCa4O(BO3)3, YCOB) is capable of being grown with apertures exceeding 100 mm, which makes it possible for application in systems of petawatt scale. In this paper, we experimentally demonstrated for the first time to our knowledge, an ultra-broadband non-collinear optical parametric amplifier with YCOB for petawatt-scale compressed pulse generation at 800 nm. Based on the SG-II 5 PW facility, amplified signal energy of approximately 40 J was achieved and pump-to-signal conversion efficiency was up to 42.3%. A gain bandwidth of 87 nm was realized and supported a compressed pulse duration of 22.3 fs. The near-field and wavefront aberration represented excellent characteristics, which were comparable with those achieved in lithium triborate-based amplifiers. These results verified the great potential for YCOB utilization in the future.
optical parametric amplification petawatt ultra-short pulse yttrium calcium oxyborate 
High Power Laser Science and Engineering
2023, 11(1): 010000e2
梁彦 1,2易友建 2,3朱坪 2,*张栋俊 2,3[ ... ]朱健强 1,2,3,***
作者单位
摘要
1 上海科技大学物质科学与技术学院, 上海 200120
2 中国科学院上海光学精密机械研究所, 上海 201800
3 中国科学院大学材料与光电研究中心, 北京 100049
提出一种基于全光纤光谱干涉的多路超短脉冲大动态范围时间同步单次测量方法,弥补了非线性相关法测量同步状态时测量范围小和示波器测量时分辨率差的不足,解决了同步测量中空间光路的复杂性和单次实时测量的难题。首先对多路光纤阵列干涉测量进行仿真计算,然后设计四路脉冲传输的光路并在实验中验证多路同步单次测量方法的可行性,最后详细分析测量误差的来源和影响。该测量方法的最小同步时间精度为5.3 fs,测量范围为1.055~14.751 ps,与仿真结果有较好的一致性。该测量方法具有光纤链路易于集成、光谱干涉数据处理速度快、测量信号能量需求低等优势,在多路超短脉冲激光相干合束系统中有重要应用前景。
测量 同步测量 超短脉冲 光谱干涉 光纤阵列 单次测量 
中国激光
2021, 48(16): 1604003
康俊 1,*崔自若 1,2,**朱坪 1高奇 1[ ... ]朱健强 1
作者单位
摘要
1 中国科学院上海光学精密机械研究所高功率激光物理联合实验室, 上海 201800
2 中国科学院大学材料与光电研究中心, 北京 100049
由于超短超强激光装置中光谱带宽较宽,使用传统的空间滤波器透镜组扩束会导致装置色差的积累,严重影响终端焦斑的质量。介绍了国内外用于超短超强激光装置中消除色差影响的主要技术与研究进展,对比总结了几种主要方案的优缺点,并提出了一种可动态精确补偿装置色差的方案,经实验验证已应用于实际工程中。最后对色差补偿的发展方向进行了分析与展望。
超快激光 色差 脉冲时间延迟 色差预补偿 
激光与光电子学进展
2020, 57(9): 090001
张栋俊 1,2朱坪 1,**谢兴龙 1,*康俊 1[ ... ]朱健强 1
作者单位
摘要
1 中国科学院上海光学精密机械研究所高功率激光物理联合实验室, 上海 201800
2 中国科学院大学材料与光电研究中心, 北京 100049
等离子体镜是一种有效提升高功率超短脉冲激光信噪比的方法,但在一部分实验中使用等离子体镜后焦斑出现了退化现象。为了定量研究等离子体镜的焦斑退化问题,提出基于等离子体膨胀和衍射传输的时空聚焦多步传输算法,通过光束质量评价函数定量分析等离子体膨胀时间、波前误差幅值和空间频率对焦斑退化的影响。仿真结果表明,等离子体镜引起的远场焦斑退化主要是由等离子体膨胀时间和波前误差引起的等离子体膨胀不均匀所致,其中,等离子体膨胀时间是主导因素。并且波前误差的幅度越大、空间频率越低,对聚焦能力的影响相对越大。从高信噪比、高功率激光系统输出能力的角度考虑,对于使用等离子体镜的高功率超短脉冲激光系统提出时空上的光束质量要求,以避免远场焦斑的退化问题。
超快光学 等离子体镜 等离子体膨胀 波前误差 傅里叶变换 
光学学报
2020, 40(2): 0232001
作者单位
摘要
1 中国科学院上海光学精密机械研究所高功率激光物理联合实验室, 上海 201800
2 中国科学院大学材料与光电研究中心, 北京 100049
高功率超短脉冲激光系统中,空间滤波器透射元件引入的色差会影响系统的聚焦功率密度。针对这一问题,提出一种具备动态调节能力的色差预补偿方案。该方案由正负透镜和反射系统构成共焦像传递系统,能够实现全系统色差的动态精确补偿。基于该方案为神光-II 5 PW(SG-II 5 PW)激光系统设计并搭建了色差预补偿光路。实验结果表明,通过精密调节该单元内部透镜间距能够精确补偿全系统的色差,显著提升系统峰值功率密度。经过色差补偿后,在SG-II 5 PW系统开展质子加速实验,获得了超过16 MeV的质子产额。
激光光学 高功率超短脉冲激光 宽带激光 空间滤波器 色差 传输时间延迟 
中国激光
2019, 46(9): 0905001
Author Affiliations
Abstract
Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
Temporal contrast is one of the crucial physical determinants which guarantee the successful performance of laser–matter interaction experiments. We generally reviewed the influences on the temporal contrast in three categories of noises based on the requirement by the physical mechanisms. The spatiotemporal influences on temporal contrast at the focal region of the chromatic aberration and propagation time difference introduced by large-aperture broadband spatial filters, which were spatiotemporally coupled with compression and focusing, were calculated and discussed with a practical case in SG-II 5 PW ultrashort petawatt laser. The system-wide spatiotemporal coupling existing in large-aperture broadband ultrashort petawatt lasers was proved to be one of the possible causes of temporal contrast degradation in the focal region.
chromatic aberration spatiotemporal coupling temporal contrast ultrashort petawatt lasers 
High Power Laser Science and Engineering
2018, 6(1): 010000e8
Author Affiliations
Abstract
1 National Laboratory on High Power Laser and Physics, Shanghai 201800, China
2 Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
3 Shanghai Institute of Laser Plasma, Chinese Academy of Engineering and Physics, Shanghai 201800, China
In this paper, we review the status of the multifunctional experimental platform at the National Laboratory of High Power Laser and Physics (NLHPLP). The platform, including the SG-II laser facility, SG-II 9th beam, SG-II upgrade (SG-II UP) facility, and SG-II 5 PW facility, is operational and available for interested scientists studying inertial confinement fusion (ICF) and a broad range of high-energy-density physics. These facilities can provide important experimental capabilities by combining different pulse widths of nanosecond, picosecond, and femtosecond scales. In addition, the SG-II UP facility, consisting of a single petawatt system and an eight-beam nanosecond system, is introduced including several laser technologies that have been developed to ensure the performance of the facility. Recent developments of the SG-II 5 PW facility are also presented.
high-power laser facility inertial confinement fusion solid-state amplifier 
High Power Laser Science and Engineering
2018, 6(4): 04000e55
Author Affiliations
Abstract
1 National Laboratory on High Power Laser and Physics , Shanghai Institute of Optics and Fine Mechanics , Chinese Academy of Sciences , Shanghai 201800 , China
2 University of Chinese Academy of Sciences , Beijing 100049 , China
We present the design and experiment of a broadband optical parametric chirped-pulse amplifier (OPCPA) which provides high conversion efficiency and good beam quality at 808 nm wavelength. Using a three-dimensional spatial and temporal numerical model, several design considerations necessary to achieve high conversion efficiency, good beam quality and good output stability are discussed. To improve the conversion efficiency and broaden the amplified signal bandwidth simultaneously, the nonlinear crystal length and OPCPA parameters are analyzed and optimized with the concept of dissipating amplified idler between optical parametric amplification (OPA) of two crystals configuration. In the experiment, an amplifier consisting of two OPCPA stages of ‘L’ type configuration was demonstrated by using the optimized parameters. An amplified signal energy of 160 mJ was achieved with a total pump-to-signal efficiency of 35% (43% efficiency for the OPCPA stage 2). The output bandwidth of signal pulse reached 80 nm and the signal pulse was compressed to 24 fs. The energy stability reached 1.67% RMS at 3% pump energy variation. The optimized OPCPA amplifier operates at a repetition rate of 1 Hz and is used as a front-end injection for the main amplifier of SG-II 5PW laser facility.
BBO nonlinear optics optical parametric chirped-pulse amplifier petawatt laser 
High Power Laser Science and Engineering
2018, 6(4): 04000e58
Jianqiang Zhu 1,2Xinglong Xie 1,2,*Meizhi Sun 1,2Jun Kang 1,2[ ... ]Zunqi Lin 1,2
Author Affiliations
Abstract
1 National Laboratory on High Power Laser and Physics, Shanghai 201800, China
2 Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
3 University of Chinese Academy of Sciences, Beijing 100049, China
We present a recent progress of the SG-II 5PW facility, which designed a multi-petawatt ultrashort pulse laser based on optical parametric chirped-pulse amplification (OPCPA). The prior two optical parametric amplifiers have been accomplished and chirped pulses with an energy of 49.7 J and a full-width-at-half-maximum (FWHM) spectrum bandwidth of 85 nm have been achieved. In the PW-scale optical parametric amplification (OPA), with the pump pulse that has an energy of 118 J from the second harmonic generation of the SG-II 7th beam, the pump-to-signal conversion efficiency is up to 41.9%, which to the best of our knowledge is the highest among all of the reported values for OPCPA systems. The compressed pulse is higher than 37 J in 21 fs (1.76 PW), and the focal spot is ${\sim}10~\unicode[STIX]{x03BC}\text{m}$ after the closed-loop corrections by the adaptive optics. Limited by the repetition of the pump laser, the SG-II 5PW facility operates one shot per hour. It has successfully been employed for high energy physics experiments.
conversion efficiency multi-petawatt optical parametric amplification proton acceleration ultrashort pulse. 
High Power Laser Science and Engineering
2018, 6(2): 02000e29
周剑 1,2孙美智 1梁潇 1,2康俊 1[ ... ]林尊琪 1
作者单位
摘要
1 中国科学院上海光学精密机械研究所高功率激光物理国家实验室, 上海 201800
2 中国科学院大学, 北京 100049
为了提高神光II 5 PW (SGII-5 PW) 超短脉冲激光系统的运行安全性, 针对大能量光参量啁啾脉冲放大(OPCPA)光束近场分布均匀性问题, 从理论上进行了数值模拟, 并与实验数据进行了对比分析。在1 PW级放大器模拟中, 以预放大器以及神光II大能量抽运脉冲的测量数据为基础, 利用参量耦合波方程组数值模拟方法, 得到了近场填充因子与光通量对比度在光参量放大过程中的演变, 并结合转换效率与输出稳定性进行讨论, 得到了对应于高光束质量、高转换效率与高稳定性的非线性晶体长度优化范围, 结果还表明抽运光对放大后光束均匀性影响较大, 进一步提升神光II第7路光束质量是大幅提升第2级OPCPA (OPCPA-II)光束均匀性的切实途径。
非线性光学 光参量啁啾脉冲放大 非共线相位匹配 填充因子 通量对比度 
中国激光
2017, 44(8): 0801007

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!